HUABANG V600 series Low-voltage inverter, excellent performance, rich function, easy-to-use, reliable, complete specifications, widely used in more than 80 countries in China and abroad in various fields of application, has been widely recognized by customers.
Applicable occasions: Fans, pumps, machine tools, textile machinery, rubber and plastic machinery, lifting, oil fields, printing and packaging, air compressors and other industries.
Chapter 1 Safety Information and Precautions
In this manual, the notices are graded based on the degree of danger:
DANGER indicates that failure to comply with the notice will result in severe personal injury or even death.
WARNING indicates that failure to comply with the notice will result in personal injury or property damage.
Read this manual carefully so that you have a thorough understanding. Installation, commissioning or maintenance may be performed in conjunction with this chapter. We will assume no liability or responsibility for any injury or loss caused by improper operation.
1.1 Safety Information and Precautions
Chapter 2 Product Information
HUABANG V600 series Low-voltage inverter, excellent performance, rich function, easy-to-use, reliable, complete specifications, widely used in more than 80 countries in China and abroad in various fields of application, has been widely recognized by customers.
Applicable occasions: Fans, pumps, machine tools, textile machinery, rubber and plastic machinery, lifting, oil fields, printing and packaging, air compressors and other industries.
2.1 Model No.
2.2 Sticker
Product : AC Motor Drive
Model : V600- XXXXX
Input : Three phase AC 380V 50/60Hz
Output: Three phase AC 0 ~ 380V 0 -300Hz
Serial No. XXXXXXXXXXXX
HUABANG ELECTRIC TECHNOLOGY CO.,LTD
2.3 Technical specification
2.4 Anatomical Drawing
2.5 Peripheral Electrical Devices and System Configuration
2.6 Main Circuit wiring
P+ | P- | R | S | T | U | V | W | PB | E |
INPUT | MOTOR | GROUND |
P+ and PB connect with Brake resistance for A type
P | P+ | P- | R | S | T | U | V | W | PB | E |
INPUT | MOTOR | GROUND |
P and P- connect with Brake unit
2.61 Main circuit terminal function explaination
Mark | Function |
P | Between P and P+ able to connect the DC electric reactor |
P+ | DC-link voltage positive terminal |
P- | DC-link voltage nagtive terminal |
PB | P+ and PB connect with Brake resistance |
R,S,T | AC three phase Power |
U,V,W | AC three phase motor |
E | Earth |
2.62 Control circuit terminal explanation
2.63 Control Board jumper Description
2.7 Basic operation distribution diagram