Product Description
Please note this inverter is Europe Standard 220V
If you need US Standard 120V, please click here to order.
Overview
This single-phase off-grid SPF series is suitable for small off-grid systems. It is an inverse control integrated machine with
built-in MPPT controller. It can support the access of mains and diesel generators. It has a beautiful appearance, compact
structure, and supports multiple monitoring methods.
Feature
——Integrated MPPT controller
——The priority of mains and photovoltaic power supply can be set
——Compatible with lead-acid and lithium batteries
——Optional WIFI or GPRS remote communication module
——Maximum support 6 single-phase or three-phase parallel
1.This single-phase off-grid SPF series is suitable for small off-grid systems.
2.It is an inverse control integrated machine with built-in MPPT controller.
3.It can support the access of mains and diesel generators. It has a beautiful appearance,
4.compact structure, and supports multiple monitoring methods.
Specifications
Datasheet |
SPF 3000TL HVM-24 |
SPF 3000TL HVM-48 |
||
Battery voltage |
24VDC |
48VDC |
||
INVERTER OUTPUT |
||||
RATED POWER |
3000VA/ 3000W |
3000VA/ 3000W |
||
Parallel Capability |
Yes |
Yes |
||
AC Voltage Regulation (Battery Mode) |
120VAC ± 5% @ 50/60Hz |
120VAC ± 5% @ 50/60Hz |
||
Surge Power |
6000VA |
6000VA |
||
Efficiency (Peak) |
93% |
93% |
||
Waveform |
Pure sine wave |
Pure sine wave |
||
Transfer Time |
10 ms (For Personal Computers); 20 ms (For Home Appliances) |
10 ms (For Personal Computers); 20 ms (For Home Appliances) |
||
SOLAR CHARGER |
||||
Maximum PV Array Power |
1500W |
1800W |
||
MPPT Range @ Operating Voltage |
30VDC ~ 80VDC |
60VDC ~ 115VDC |
||
Maximum PV Array Open Circuit Voltage |
102VDC |
145VDC |
||
Maximum Solar Charge Current |
50A |
30A |
||
Maximum Efficiency |
98% |
98% |
||
Standby Power Consumption |
2 W |
2 W |